LED Strobe Controller
- Compatible with nearly any LED lighting assembly available today
- Eight independently controlled output channels
- Ethernet or RS232 interface options
- Pulsed output up to 20A on each channel
- 8 channel output
- Ethernet interface (PP820)
- 20A maximum pulsed
- 2A and 5A maximum pulse options
- 2A maximum continuous
- Supply voltage 12-48V DC
- 4µS minimum pulse width.
The PP820 can be quickly configured using our free software which can be downloaded from this page, or for the PP820 Ethernet enabled controller range simply by accessing the controller via your internet browser; type in the IP address for the controller into your browser and you have full access to all of the parameters.
If you are using a third party software package the PP820 range has a simple command set that is detailed in the manual allowing easy communication. As with all Gardasoft products, all the settings are stored in non-volatile memory, and it will retain these settings even when the Ethernet connection is disconnected. Gardasoft Controllers are universally compatible with LED Vision lighting, from manufacturers such as CCS.
| Specification | |
| Output channels | 8 independent constant current output channels |
| Output current options | PP820: Controllable in steps of approx 100mA. Up to 20A pulsed or 2A continuous PP820C: Controllable in steps of approx 5mA. Up to 20A pulsed or 2A continuous PP821: Controllable in steps of approx 10mA. Up to 2A pulsed or 2A continuous PP821C: Controllable in steps of approx 2mA. Up to 2A pulsed or 2A continuous PP822: Controllable in steps of approx 24mA. Up to 5A pulsed or 2A continuous PP822C: Controllable in steps of approx 2mA. Up to 5A pulsed or 2A continuous |
| Trigger inputs | 8 opto-isolated digital inputs |
| Pulse width timing | From 4 microseconds to 300 milliseconds in steps of 1 microsecond. Timing repeatability 100 nanoseconds |
| Delay from trigger to pulse | From 4 microseconds to 300 milliseconds in steps of 1 microsecond. Timing repeatability 2 microseconds (depending on conditions) |
| Supply voltage | Unregulated or regulated 12V to 48V |
| Configuration | Ethernet, using TCP/IP or UDP. Configured using a web browser, Gardasoft’s configuration program or from the user’s application software |
| Dimensions | 215mm long by 54mm wide by 86mm high |
| Weight | 600g |
| Mounting | Panel mounting. Six M4 tapped holes |